欧亚乱奸视频,激情亚洲区第一页,国产乱码视频在线观看,97资源站超碰,福利精品午夜视频网,国产精品视频高潮8,中文字幕一区二区精品,天堂一区二区三区四区,国产二区九九精品

Muen
News

News

Enterprise service provider

location : Home > News > Technical information

When the drive short-circuit fault, what are the reasons?

2023-05-20 11:28:06

Converter and inverter technology is the application of microelectronic technology, a power control device for controlling the AC motor by changing the frequency of the motor operating power mode.


The main drive motor is used to adjust the speed, there are two aspects of the application:


1. Energy is mainly fan and pump load, the frequency converter using direct power than the power grid, so that energy saving, energy saving can reach a ratio of more than 50%, the energy saving effect of the process on specific operation of the motor. Often a large number of energy-saving motors can be run at low speeds, if the motor is always running at full capacity, it is also no need to use the drive.


2. The process requirements, in metallurgy, petroleum, chemical, textile, electricity, building materials, coal and other industries, some technology does not allow direct motor starting, we need to meet the technological requirements of Frequency Control and coordination. This is a must drive. Such as metallurgical industry need drive motor about 70%.


In the course of the drive, a short-circuit failure occurs. So, what are the reasons of the inverter is short-circuited?


1. The inverter short-circuit failure usually occurs during operation, when the reset start again, the speed control system increases the speed of the drive inverter short circuit protection.


2. Drive a short-circuit failure has a great impact on current, modern inverter has no time limit quick break protection, when a short circuit fault, as long as no time limit quick break protection and reliable action, would not have caused the short circuit current inverter damage. Since no protective action time of speed off very rapidly, it is difficult to observe the size of the short-circuit current, and therefore provided for the fault record inverter fault parameters can be obtained in the record.


3. The short-circuit the output side of the inverter output to drive mainly in short circuit protection of which a substantial part of the connection cable between the motor phase short circuit occurs inside the motor short circuit or the like, cable and motor failures account.


4. The frequency converter itself is not working properly, as abnormal two inverter devices in the inverter bridge of the same bridge arm continues to appear in alternating operation. For example, the ambient temperature is too high or the inverter device itself aging and other reasons, so that the inverter device parameter changes, resulting in the alternate process, a device has been turned on, the other device has not yet had time off, causing the same an upper arm, the two devices "through", the positive DC voltage, between the negative electrode are short-circuited.


安邦信


label

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標(biāo)題-8.png 0755-81719517
未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
濮阳市| 繁昌县| 平果县| 拜泉县| 吉木乃县| 兴安县| 迁西县| 祁门县| 西安市| 镇平县| 合阳县| 澜沧| 辽中县| 普宁市| 九台市| 凤台县| 奉化市| 阳西县| 二连浩特市| 澄迈县| 松桃| 城步| 衡东县| 六盘水市| 苍梧县| 高青县| 乾安县| 泸西县| 上林县| 涿州市| 慈利县| 北京市| 湛江市| 桦南县| 同仁县| 宝鸡市| 建瓯市| 涪陵区| 报价| 隆昌县| 昌邑市|